Mayar HoldingMAYAR GULF INDUSTRIAL COMPANY

ENGINEERED FOR PERFORMANCE

Magnetic components.
Powering industry.

Transformers, chokes and reactors built around your application. Serving Saudi Arabia and the wider GCC.

CUSTOM ENGINEERING / LOW-VOLTAGE SOLUTIONS

Mayar Gulf industrial transformers and drive chokes displayed on dark platformsBUILT FOR INDUSTRY. BUILT FOR YOUR APPLICATION.
30 VA–200 kVATransformer & autotransformer range
2 A–500 AReactor & choke current range
600–1,000Units produced per month
100%Routine tested before dispatch

01 / OUR PRODUCTS

The right component.
For every application.

Five product families. Flexible ratings, voltage combinations and mechanical configurations, engineered to your specification.

01Three control transformers with orange terminals

Control transformers

Isolated control voltage for panels, PLCs, relays and automation circuits.

Technical overview +

Typical ratingsSingle phase: 25 VA–5 kVA
Three phase: 25 VA–5 kVA; customizable

Frequency50 / 60 Hz

ApplicationsControl panels, CNC machines, packaging and textile machinery.

Full specifications ↗
02Dry-type step-up and step-down transformer

Step-up / step-down

Match supply voltage to machinery, testing systems and renewable energy projects.

Technical overview +

Typical ratingsSingle phase: 100 VA–50 kVA
Three phase: 500 VA–200 kVA, or as required

Voltage110–220–380–440–480–600 V, or as required

ConfigurationSingle or three phase. Step-up or step-down fixed at order stage.

Full specifications ↗
03Three-phase shielded isolation transformer

Isolation transformers

Galvanic separation for sensitive equipment, instrumentation and automation.

Technical overview +

Configuration1:1 isolation, or isolation combined with step-up / step-down

ShieldingOptional grounded electrostatic shield between windings

Ratings & voltageProject specific, 50 / 60 Hz

Full specifications ↗
04Mayar Gulf drive choke assemblies

Drive chokes

Limit current distortion and switching stress in VFD and motor drive systems.

Technical overview +

Typical rated current5 A–500 A, or as required

ImpedanceTypically 2–5%, specified by application

PositionLine input, load / motor output or DC link, as specified

Full specifications ↗
05Industrial reactor assemblies

Reactors

Current limiting and harmonic conditioning for industrial power systems.

Technical overview +

DesignIron-core or air-core construction, per application

InductanceSpecified in mH / μH or by impedance requirement

ApplicationsPower factor correction, harmonic filters and industrial drives.

Full specifications ↗

PRODUCT CATALOGUE 2026

All the technical
detail you need.

Specifications, application areas, testing and customization in one place.

Download the catalogue ↓PDF · 20 PAGES

02 / MAYAR GULF

Built around
your requirements.

Industrial magnetic and power-quality solutions for the systems that keep your business moving.

Mayar Gulf Industrial Company supports panel builders, OEMs, automation integrators, machinery manufacturers and EPC projects across Saudi Arabia and the wider GCC.

From electrical ratings to terminals and enclosures, each product family can be tailored to the application, with designs referenced to recognized IEC standards.

50%Customized / project-specific designs
20Skilled engineering & production staff

ACROSS INDUSTRIES

Where our solutions work.

Industrial automationSwitchboards & switchgearMachine tools & CNCRenewable energyOil, gas & petrochemicalWater & desalinationData centersPower factor correction

03 / QUALITY & TESTING

Every unit.
Tested before dispatch.

Routine testing is supported by calibrated, traceable instrumentation. Factory Acceptance Testing can be arranged for client, consultant or third-party witness on request.

01

Electrical verification

Winding resistance, voltage ratio and polarity, no-load loss and current, and load loss and impedance voltage.

02

Insulation integrity

Insulation resistance, applied-voltage withstand and induced-voltage withstand testing.

03

Documented performance

Functional checks of taps and accessories, with applicable standards confirmed in the technical offer and test certificate.

Design references include IEC 61558 and IEC 60076. Exact standards and editions depend on the selected product and application.

LET’S BUILD YOUR SOLUTION

Send an enquiry.

Tell us what you need. Our team will help with specifications, pricing and availability.

Your details will be used to respond to your enquiry.

Mayar HoldingMAYAR GULF INDUSTRIAL COMPANY
Mayar Gulf Industrial Company
King Abdul Aziz Road, Ar Rafaie, Al Kharj
Riyadh, Kingdom of Saudi Arabia
Download Catalogue ↓